100% Factory Original
Lowest Price
Free & Fast Shipping
Product on sale

FCHAO 4000W 24V 230V Off-Grid Hybrid Inverter with Combiner Box

Brand: FCHAO

From $319.49

16 продуктів, проданих за останні 14 год 
Продаж швидко! Понад 11 людей мають у своєму кошику 

【Features】The 4000W 24V 230V DC input off-grid hybrid inverter comes in two models – a standard version and a version with a built-in combiner box – allowing you to choose the one that best suits your needs.
【EU Direct Only】030KHP-4000W shipped from the European warehouse come equipped with a Wi-Fi module and a remote controller. Please review our Shipping Policy to confirm whether delivery is available.

30 people are viewing this right now
  • Check Mark Estimated Delivery : Shipments from our local warehouse take up to 7 days; shipments from the factory take approximately 10-30 days.
  • Check Mark Free Shipping : Free shipping to most countries and regions.
  • Stripe
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

4000W 24V hybrid Inverter with/without Combiner Box

Brand-new Hybrid Charger Inverter

This FCHAO 4000W 24V 230V inverter is an all-in-one hybrid inverter/charger, a new type of off-grid solar inverter that integrates the functions of an inverter, solar charger, AC charger, uninterruptible power supply (UPS), and combiner box.

Integrated with photovoltaic combiner box

This new 4000W off-grid inverter comes in two optional models. The 030KHP-4000W-05HL features a highly practical design, integrating the necessary PV combiner box and incorporating a PV circuit breaker, PV surge protector, grid input circuit breaker, inverter output circuit breaker, and battery circuit breaker. The 030KHP-4000W-05A is the standard functional model.

Wi-Fi & APP remote Control

The inverter is equipped with a Wi-Fi module, allowing users to connect via Wi-Fi and install the FCHAO app on their mobile phones. The inverter’s operating data will then be accurately displayed on the phone, enabling better control and monitoring of the inverter’s status.

Capable of operating with or without a battery.

The FCHAO 4000W charger hybrid inverter has two operating modes: with battery and without battery. In the former mode, when both solar power and grid power are available, the inverter will enter hybrid inversion mode; when neither solar power nor grid power is available, the inverter system will automatically switch to battery power, providing backup power for daily emergencies.

In the latter mode, when both solar power and grid power are available, solar power will be prioritized; if the power supply is insufficient, it will be supplemented by grid power. However, when neither solar power nor grid power is available, there will be no power supply during emergencies due to the lack of battery storage. Therefore, it is recommended to have a backup battery or generator.

Wide range of application scenarios

The FCHAO 4000W hybrid inverter features stable and efficient conversion efficiency, making it suitable for various applications including rooftop solar systems, RVs, campervans, yachts, home appliances, power tools, office equipment, and portable devices4

Weight N/A
Dimensions N/A
Models

Built-in Combiner Box, Standard

SKU

030KHP-4000W-05HL with Combiner Box , 030KHP-4000W-05A

Grid Mode

—–

Nominal Input Voltage

230Vac

Input Voltage Range

90V~280Vac(±2%);170V~280Vac(±2%)

Nominal Input Frequency

50Hz/60Hz (Auto Detection)

Overload / Short Circuit Protection

Circuit Breaker

Transfer Time (Bypass↔Inverter)

10ms (Typical Value)

AC Backfeed Protection

Yes

Max. Bypass Overload Current

5.5KW (25A)

Inverter Mode

—————————-

Nominal Output Power

4.2KW

Nominal Output Voltage

230Vac

Output Voltage Waveform

Pure Sine Wave

Output Frequency (Adjustable)

50Hz/60Hz

Maximum Efficiency

88%~90%

Peak Power

1×/(2×Rated Power 0.3s)

Nominal Battery Voltage

24V (Minimum Start Voltage:22V)

Battery Input Voltage Range

20V~32Vdc±0.5v

Low Battery Alarm

Load ≥ 50% 21.0V;
Load <50% 22.0V

Undervoltage Protection (Adjustable)

Load ≥ 50% 20.0V;
Load < 50% 21.0V

Undervoltage Recovery

@Reset Inverter Switch; @AC Charge Activation; @PV Charge Activation

Overvoltage Protection

32.0Vdc ± 0.5v

Overvoltage Recovery

31.0Vdc ± 0.5v

No-load Power Consumption

≈1.47A(36W/24V)

AC Charging

———————

Battery Types

Lead-Acid or Lithium Battery

Maximum Charging Current (Adjustable)

100A±5A

Charging Voltage Range (Adjustable)

24V~30Vdc

Overcharge Protection

Alarm and Stop Charging After 1 Minute

PV Charging

——————-

Maximum PV Open-circuit Voltage

500Vdc

MPPT Voltage Range

65V~450Vdc

Maximum PV Input Power

4.5KW

Maximum PV Input Current

10A

PV Charging Current Range (Adjustable)

100A±5A

Connection Protection

Reverse Polarity Protection

Supply Mode & Charging Mode (Operating Mode)

—————————-

Grid Priority Mode (Default)

When grid power is normal, the system draws power directly from the utility to supply loads and charge
batteries. In the event of a grid outage, it automatically transfers seamlessly to battery inverter output
with zero interruption, serving as a UPS-equivalent backup power source. Power Supply Priority: Grid First → Solar Second → Battery Backup

Photovoltaic Priority

The system prioritizes PV power supply. When PV output is insufficient or unavailable, it automatically
switches to utility power for load supply and battery charging. Power Supply Priority: Solar First → Grid Second → Battery Backup

Inverter Priority

The inverter delivers continuous power when battery voltage stays within the normal range. If battery
voltage drops below the threshold set at [Parameter 12], the system automatically transfers to utility
power. After the battery is fully charged or reaches the preset value of [Parameter 13], the system
automatically reverts to inverter output. Power Supply Priority: Battery First → Solar Second → Grid Backup

Hybrid Load Supply

When photovoltaic energy is insufficient, both the PV system and the grid power supply jointly provide
electricity to the load; when photovoltaic energy is sufficient, priority is given to charging the battery, with any surplus power being utilized in conjunction with the grid for load support. If parameter [ Item 16 ] is set to OSO (PVOnly Charging Mode), the mains power does not
participate in the battery charging process.

Hybrid Charging

PV and utility power can charge simultaneously, with priority given to solar. When PV power is
insufficient, utility power automatically supplements; when PV output is sufficient, utility power cuts off
automatically.

Photovoltaic Charging Only

Charged solely by photovoltaic power, without the use of mains electricity.